{"id":8772,"date":"2022-09-07T11:01:53","date_gmt":"2022-09-07T09:01:53","guid":{"rendered":"https:\/\/garnet.it\/?p=8772"},"modified":"2022-09-07T11:01:54","modified_gmt":"2022-09-07T09:01:54","slug":"igbt-modules-for-high-power-ups-fuji-electric","status":"publish","type":"post","link":"https:\/\/garnet.it\/en\/igbt-modules-for-high-power-ups-fuji-electric\/","title":{"rendered":"IGBT modules for high power UPS &#8211; Fuji Electric"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">IGBT modules for Online Ups: operating principle of uninterruptible power supplies<\/h3>\n\n\n\n<p>Online double conversion UPS systems are used for sensitive equipment protection (bank servers, hospital operating rooms, etc.) that require uninterrupted power supply during critical situations (example blackout).<\/p>\n\n\n\n<p>When occurs a voltage drop at the UPS input, the system is still able to keep the output voltage perfectly stable.<\/p>\n\n\n\n<p>The battery pack, which is continuously charged from the electricity network, has the purpose of intervening during blackout by supplying the load and ensuring service continuity.<\/p>\n\n\n\n<p>The input mains voltage (220V \/ 380V) initially passes through a rectifier bridge which transforms it into direct current (DC) to recharge the batteries and, subsequently, passes through an inverter which transforms and stabilizes it into alternating current to power the batteries.<\/p>\n\n\n\n<p>The By-pass network is used in the event of malfunctions and \/ or battery replacements.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"679\" height=\"366\" src=\"https:\/\/garnet.it\/wp-content\/uploads\/2022\/09\/image.jpg\" alt=\"\" class=\"wp-image-8808\" title=\"\" srcset=\"https:\/\/garnet.it\/wp-content\/uploads\/2022\/09\/image.jpg 679w, https:\/\/garnet.it\/wp-content\/uploads\/2022\/09\/image-300x162.jpg 300w, https:\/\/garnet.it\/wp-content\/uploads\/2022\/09\/image-640x345.jpg 640w\" sizes=\"auto, (max-width: 639px) 98vw, (max-width: 1199px) 64vw, 679px\" \/><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Fuji Electric IGBT modules for Ups<\/h3>\n\n\n\n<p><a href=\"https:\/\/garnet.it\/en\/partner\/fuji-electric-en\/\" target=\"_blank\" rel=\"noreferrer noopener\">Fuji Electric<\/a> is a global manufacturer and supplier of IGBT modules, inverters and power semiconductors also used for<strong> UPS uninterruptible power supplies.<\/strong><\/p>\n\n\n\n<p>The type of <strong>IGBT modules<\/strong> most suitable for <strong>uninterruptible power supplies<\/strong> depends on the power of the individual UPS:<\/p>\n\n\n\n<ol class=\"wp-block-list\"><li>IGBT modules for low power UPS: <strong>Discrete<\/strong>;<\/li><li>IGBT modules for medium and high power UPS: <strong>2-levels<\/strong> and <strong>3-levels<\/strong> topologies<\/li><\/ol>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Power \/ topologies<\/strong><\/td><td><strong>MEDIUM \/ 2-levels<\/strong><\/td><td><strong>MEDIUM-HIGH \/ 2-levels<\/strong><\/td><td><strong>HIGH <strong>\/ 2-levels<\/strong><\/strong><\/td><td><strong><strong>HIGH<\/strong> <strong>\/ 3-levels<\/strong><\/strong><\/td><\/tr><tr><td><strong>Tensions<\/strong> <strong>(V)<\/strong><\/td><td>1200 &#8211; 1700<\/td><td>650 \u2013 1200 -1700<\/td><td>1200 &#8211; 1700<\/td><td>1200<\/td><\/tr><tr><td><strong>Currents (A)<\/strong><\/td><td>50 \u2013 250 A<\/td><td>150 &#8211; 600<\/td><td>600-1800<\/td><td>650 \/ 900<\/td><\/tr><tr><td><strong>Package<\/strong><\/td><td>Standard \/ 6Pack<\/td><td>STD \/ Dual XT<\/td><td>Prime Pack<\/td><td>STD \/ Prime Pack<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1005\" height=\"206\" src=\"https:\/\/garnet.it\/wp-content\/uploads\/2022\/07\/image-9.png\" alt=\"\" class=\"wp-image-8785\" title=\"\" srcset=\"https:\/\/garnet.it\/wp-content\/uploads\/2022\/07\/image-9.png 1005w, https:\/\/garnet.it\/wp-content\/uploads\/2022\/07\/image-9-300x61.png 300w, https:\/\/garnet.it\/wp-content\/uploads\/2022\/07\/image-9-768x157.png 768w, https:\/\/garnet.it\/wp-content\/uploads\/2022\/07\/image-9-640x131.png 640w\" sizes=\"auto, (max-width: 639px) 98vw, (max-width: 1199px) 64vw, 770px\" \/><\/figure>\n\n\n\n<ul class=\"wp-block-list\"><li>IGBT Modules for High Power UPS (<strong>2\/3 Levels<\/strong>)<\/li><\/ul>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1004\" height=\"452\" src=\"https:\/\/garnet.it\/wp-content\/uploads\/2022\/09\/image-6.png\" alt=\"\" class=\"wp-image-8801\" title=\"\" srcset=\"https:\/\/garnet.it\/wp-content\/uploads\/2022\/09\/image-6.png 1004w, https:\/\/garnet.it\/wp-content\/uploads\/2022\/09\/image-6-300x135.png 300w, https:\/\/garnet.it\/wp-content\/uploads\/2022\/09\/image-6-768x346.png 768w, https:\/\/garnet.it\/wp-content\/uploads\/2022\/09\/image-6-640x288.png 640w\" sizes=\"auto, (max-width: 639px) 98vw, (max-width: 1199px) 64vw, 770px\" \/><\/figure><\/div>\n\n\n\n<ul class=\"wp-block-list\"><li><strong>3-level systems<\/strong>:<\/li><\/ul>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/garnet.it\/wp-content\/uploads\/2022\/07\/image-8.png\" alt=\"\" class=\"wp-image-8784\" width=\"951\" height=\"507\" title=\"\" srcset=\"https:\/\/garnet.it\/wp-content\/uploads\/2022\/07\/image-8.png 1004w, https:\/\/garnet.it\/wp-content\/uploads\/2022\/07\/image-8-300x160.png 300w, https:\/\/garnet.it\/wp-content\/uploads\/2022\/07\/image-8-768x410.png 768w, https:\/\/garnet.it\/wp-content\/uploads\/2022\/07\/image-8-640x342.png 640w\" sizes=\"auto, (max-width: 639px) 98vw, (max-width: 1199px) 64vw, 770px\" \/><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Advantages of using fuji electric IGBT modules<\/h3>\n\n\n\n<p>Fuji Electric&#8217;s seventh generation IGBT modules offer high performance, increased power and are easy to assemble.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li><strong>Operating Tjop = 175 \u00b0 C<\/strong>: they provide a wider operating margin in temperature, (+ 25 \u00b0 C)<\/li><li><strong>Lower Vcesat<\/strong>: lower conduction losses<\/li><li><strong>Better switching behavior<\/strong>: the overall losses (Conduction + Switching) are improved by about 10%<\/li><li><strong>New materials<\/strong>: to ensure high operational reliability<\/li><li><strong>Higher Isolation<\/strong>: Face = 4000Vrms vs. 2500Vrms (V-series)<\/li><li><strong>Greater future availability<\/strong><\/li><\/ul>\n\n\n\n<p>Garnet is <strong>Fuji Electric&#8217;s official partner in Italy and UK <\/strong>and it&#8217;s able to support its customers by providing also software simulations, useful for correctly dimensioning systems. We also have the exclusive support from Fuji Electric Senior FAE <em>Massimo Caprioli<\/em>.<\/p>\n\n\n\n<p>For more information about <strong>Fuji Electric IGBT modules for high power UPS<\/strong> you can download the catalog at the following link<a href=\"https:\/\/garnet.it\/wp-content\/uploads\/2021\/04\/Fuji_IGBTs_Catalogue2023-1.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"> Fuji Electric Power Semiconductors<\/a> and contact us at <a rel=\"noreferrer noopener\" href=\"mailto:info@garnetitalia.com\" target=\"_blank\">info@garnetitalia.com<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>IGBT modules for Online Ups: operating principle of uninterruptible power supplies Online double conversion UPS systems are used for sensitive equipment protection (bank servers, hospital operating rooms, etc.) that require uninterrupted power supply during critical situations (example blackout). When occurs a voltage drop at the UPS input, the system is still able to keep the [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":8774,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[998],"tags":[],"class_list":["post-8772","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products"],"acf":[],"_links":{"self":[{"href":"https:\/\/garnet.it\/en\/wp-json\/wp\/v2\/posts\/8772","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/garnet.it\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/garnet.it\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/garnet.it\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/garnet.it\/en\/wp-json\/wp\/v2\/comments?post=8772"}],"version-history":[{"count":21,"href":"https:\/\/garnet.it\/en\/wp-json\/wp\/v2\/posts\/8772\/revisions"}],"predecessor-version":[{"id":8809,"href":"https:\/\/garnet.it\/en\/wp-json\/wp\/v2\/posts\/8772\/revisions\/8809"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/garnet.it\/en\/wp-json\/wp\/v2\/media\/8774"}],"wp:attachment":[{"href":"https:\/\/garnet.it\/en\/wp-json\/wp\/v2\/media?parent=8772"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/garnet.it\/en\/wp-json\/wp\/v2\/categories?post=8772"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/garnet.it\/en\/wp-json\/wp\/v2\/tags?post=8772"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}